SPA480 - 1 x 480 W amplifier

wspa4120-rvfondThe SPA480 amplifier was specifically developed to meet the requirements of EN 60849 for safety installations.
Each amplifier module is fitted with its own 220 VAC/24 VDC power supply for increased system reliability. To avoid handling errors, the volume output is set using the potentiometer located at the back of the apparatus.

 
Data Sheet
SPA480
icone_pdf





Further to standard protection via fuses, SPA amplifiers also have electronic and thermal protection to protect them from all potential hazards.
A ventilator provides forced cooling for the final power shelves and internal parts of the apparatus. It starts up automatically when the heat shunt reaches a certain temperature threshold, and stops when the temperature returns to normal values.
Four LEDs display the status of each amplifiers: AC or DC power supply, Line Overload and Temperature overload.
Furthermore, a three LEDs Vu-Meter indicates the presence and level of audio signal.
A surveillance circuitry is continuously monitoring the temperature and the presence of AC and DC power supplies for both amplifiers. In case of a problem, the overload LEDs will be switched ON and the Fault relay will be activated. The channels can be bridged together in order to create a single channel amplifier with twice or four time the power.

MAIN PROPERTIES

  • Balanced 0 db inputs.
  • 100 V outputs.
  • Thermostatic ventilation.
  • Power supply internal surveillance.
  • 230 VAC and 24 VDC power supply.
  • "Amplifier status"  contact output.
  • Connexions on detachable screw-on terminal boards.