Header Pic Header Pic
Header Pic  PfeilHOME arrow SINAPS COMPACT arrow IDA4
HOMEPRODUCTSNEWSREFERENCESCONTACT
Header Pic
Header Pic

IDA4

wida-4recto-verso-fondIDA4 can support 1 PSS849 security microphone console with touchpad and can process and route another four 0 dB audio inputs into 4 different zones. Each channel is fitted with volume control, equalizers, and a programmable delay. Each 0 db input features contact and VOX activation (ideal when using the cordless microphone, for example).

 
Data Sheet
Software
IDA4
icone_pdf
 icone_exe





Four digital messages can be recorded through audio inputs or downloaded as WAV files directly from a computer into IDA. A security message is pre-programmed in 4 languages. SINAPS-Compact is fitted with 4 alarm inputs and 4 input contacts making it possible to obtain pre-programmed routings. The 4 output contacts can be used to disable the 100 V line attenuators.
As an EN 60849 security system, all SINAPS-Compact functions and peripherals are monitored. All incidents are recorded into a data file which can be consulted on the display screen. Also any detected faults are signalled by a general fault output contact. A local loudspeaker output enables selective listening to the messages and the system’s 100V output signals. Control keys and the front LCD screen can be used to configure SINAPS-Compact. Access can be password-protected.



MAIN PROPERTIES

 

  • 5 audio inputs (1 emergency broadcast microphone + 4 x 0d balanced inputs)
  • Monitoring of four 100 V Loudspeaker zones
  • Max 500W per zone /amplifier.
  • Monitoring of 4 zone amplifiers + 1 backup amplifier
  • Full monitoring of the PSS microphone console (capsule, screen, touchpad,connections)
  • Digital message player (4 messages, total length up to 2mins. 11secs.)
  • Digital signal processing (DSP)
  • Parametric equalization: 3 bands on inputs, 7 bands on outputs
  • Individual controls for each input and output level
  • Separate levels for the security sources
  • Free zone labelling
  • 9 programmable priority levels (contact or VOX audio routing)
  • Programmable delay of 0 to 683 msecs.
  • Measurements (levels and impedance) of amplifiers and LS lines
  • Incident data record with up to 2048 incidents
  • Internal clock
 
Header Pic
   
© 2008 Ateis International